Insulated Power Module - ABI Series
MAIN CHARACTERISTICS
Insulation voltage (RMS) up to 9.5 kV
Custom design to optimize circuit layout
The materials used are compliant with UL94-V0 standard and ROHS requirements
Base plate insulation using AlN substrates

Insulated Power Module type ABI | Voltage class | Devices number | VRRM | IFAV Th = 55 °C | Qrr Tj max | trr Tj max | Test condition dIF/dt | Vins rms, 1 min | Tj max | |
---|---|---|---|---|---|---|---|---|---|---|
V | A | μC | μC | A/μs | V | °C | ||||
ABI-1-ARF372HVI-A | S45 | 1 | 4500 | 64 | 100 | 1.7 | 100 | 9500 | 125 | ![]() |
ABI-1-ARF372HVI-K | S45 | 1 | 4500 | 64 | 100 | 1.7 | 100 | 9500 | 125 | ![]() |
ABI-2-AR372X2HVI | S45 | 2 | 4500 | 191 | 450 (typ) | - | - | 9500 | 150 | ![]() |
ABI-2-AR371HVIKA | S45 | 2 | 4500 | 200 | - | - | - | 9500 | 150 | ![]() |
ABI-2-ARF261AA | S33 | 2 | 3300 | D1 = 43 D2 = 24 | 45 | 1.0 | 100 | 6000 | 125 | ![]() |
ABI-2-ARF261KK | S33 | 2 | 3300 | D1 = 43 D2 = 24 | 45 | 1.0 | 100 | 6000 | 125 | ![]() |
ABI-1-AR409PC | S02 | 1 | 200 | 825 | - | - | - | 6000 | 125 | ![]() |
ABI-1-ARF261HVI-A | S33 | 1 | 3300 | 59 | 45 | 1.0 | 100 | 9500 | 125 | ![]() |
ABI-1-ARF261HVI-K | S33 | 1 | 3300 | 59 | 45 | 1.0 | 100 | 9500 | 125 | ![]() |
ABI-2-ARF261HVIAA | S33 | 2 | 3300 | D1 = 40.5 D2 = 20.0 | 45 | 1.0 | 100 | 9500 | 125 | ![]() |
ABI-2-ARF261HVIKK | S33 | 2 | 3300 | D1 = 40.5 D2 = 20.0 | 45 | 1.0 | 100 | 9500 | 125 | ![]() |
ABI-1-ARF261 | S33 | 1 | 3300 | 67 | 45 | 1.0 | 100 | 6000 | 125 | ![]() |